- Tempered Water: Twin thermostatic mixing elements respond independently to changes in incoming hot and cold water temperatures to maintain outlet temperatures to within +/-5 degrees F. Varying conditions can be up to a 30 degrees F change in hot water temperature, 30 degrees F change in cold-water temperature, and a 50% drop in inlet supply pressure. Inlet hot and cold pressures must be equal. The outlet temperature factory setting is 80 degrees F.
- Fail-Safe Back Up: Liquid thermal thermostats with tamper-resistant control adjustment. System shuts off all incoming hot water should cold water supply fail. Redundant thermostatic elements provide tempering even when one element fails. Should the hot water supply become interrupted, or the thermostatic elements fail, the valve will go into cold-water bypass flow.
- NOTE: In bypass mode, valve offers more resistance to flow than when functioning normally. Therefore, depending on facility pressure available, the fixture may not function to ANSI Standards when valve is in bypass mode.
- Maximum Inlet Pressure: 125 psi.
- Maximum Inlet Temperature: 180 degrees F.
- Minimum Inlet Temperature: 120 degrees F.
- Recommended Inlet Temperature: 140 degrees F.
- Inlet and Outlet: 1-1/4” IPS. Inlets can be connected from top or bottom. Isolation check valves are supplied for installation at inlet and outlet.